Document Type : Case Report

Authors

1 Road Traffic Injury Research Center, Emergency Department, Tabriz University of Medical Sciences, Tabriz, Iran

2 Kerman Neuroscience Research Center, Kerman University of Medical Sciences, Kerman, Iran

Abstract

We report a 54-year-old woman with the history of end-stage renal disease (ESRD) who was admitted to our hospital because of volume overload. Due to long-term use of peripheral veins and arteriovenous fistula (AVF) failure, central venous catheterization was the only choice for hemodialysis. She developed right upper extremiti’s pain and paresis during hemodialysis. A posteroanterior chest x-ray showed the catheter tip was accidently pushed from right internal jugular vein into right subclavian vein during hemodialysis by the dialysis center nurse. Therefore, we believe that the physician should be aware of any changes in the catheter size after insertion. And a chest x-ray should ensure the catheter’s correct position in any patient who develops complications.

Keywords

Main Subjects

1. Webb JG, Simmonds SD, Chan-Yan C. Central venous catheter malposition presenting as chest pain. Chest 1986; 89(2): 309-12.
2. Bankier AA, Mallek R, Wiesmayr MN, Fleischmann D, Kranz A, Kontrus M, et al. Azygos arch cannulation by central venous catheters: radiographic detection of malposition and subsequent complications. J Thorac Imaging 1997; 12(1): 64-9.
3. Moeinipour AA, Amouzeshi A, Joudi M, Fathi M, Jahanbakhsh S, Hafez S, et al. A rare central venous catheter malposition: a case report. Anesth Pain Med 2014; 4(1): e16049.
4. Muhm M, Sunder-Plassmann G, Druml W. Malposition of a dialysis catheter in the accessory hemiazygos vein. Anesth Analg 1996; 83(4): 883-5.
5. Mohan PR, Hegde H, Padmanabha S, Qureshi FM, Imran S. Malposition of central venous catheter - three case reports. IOSR Journal of Dental and
Medical Sciences 2013; 11(6): 7-9.
6. Ikeda S, Sera Y, Yamamoto H, Terakura H, Yoshida M, Uchino S, et al. Malposition of a totally implantable venous access catheter in the azygous vein: report of a case. Surg Today 1995; 25(7): 649-50.
7. Cassidy FP Jr, Zajko AB, Bron KM, Reilly JJ Jr, Peitzman AB, Steed DL. Noninfectious complications of long-term central venous catheters: radiologic evaluation and management. AJR Am J Roentgenol 1987; 149(4): 671-5.
8. Maffessanti M, Bortolotto P, Kette F, Bellis GB. Radiological detection of malpositions and complications of central venous catheters. Eur J Radiol 1989; 9(2): 101-4.
9. Chantler J. Applied anatomy of the central veins. In: Hamilton H, Bodenham AR. Central Venous Catheters. Oxford, UK: Wiley-Blackwell; 2009.
10. Kusminsky RE. Complications of central venous catheterization. J Am Coll Surg 2007; 204(4): 681-96